The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (4)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2013-0659",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 10,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "LOW",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2013-04-01T16:55:10.147",
  "references": [
    {
      "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-084-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-628113.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://ics-cert.us-cert.gov/pdf/ICSA-13-084-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-628113.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185."
    },
    {
      "lang": "es",
      "value": "La caracterítica de depuración de los interfaces Siemens CP 1604 y  CP1616 con firmware anterior a 2.5.2, permite  a atacantes remotos ejecutar código arbitrario a través de un paquete UDP especialmente manipulado al puerto 17185."
    }
  ],
  "lastModified": "2026-06-16T23:49:51.593",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:cp_1604_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "E51E02D5-F1C6-4E86-9DD6-D18F4D2EB5C9",
              "versionEndIncluding": "2.5.1"
            },
            {
              "criteria": "cpe:2.3:a:siemens:cp_1616_firmware:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "B484E289-898B-474D-BA73-BA33A8E8CF77",
              "versionEndIncluding": "2.5.1"
            },
            {
              "criteria": "cpe:2.3:h:siemens:cp_1604:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6148BD0D-5BD1-4182-8202-EBDB56B0D146"
            },
            {
              "criteria": "cpe:2.3:h:siemens:cp_1616:-:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "1D7CC79A-1446-415F-8BFF-71C82C9256BB"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}