« Volver al listado

CVE-2012-3003

Estado: ModificadaMedia (5.8)—

Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2012-3003",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 5.8,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "NONE",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 4.9,
        "baseSeverity": "MEDIUM",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2012-06-08T18:55:02.347",
  "references": [
    {
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de redirección abierta en un aplicación Web no especificada en Siemens WinCC v7.0 SP3 anterior a Update 2 permite a atacantes remotos redireccionar usuarios a otras webs y conducir ataques de phising a través de una URL en una petición GET"
    }
  ],
  "lastModified": "2026-06-16T23:42:29.843",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "111D0F4D-2B67-46E8-BF8D-5D30EFE561EE"
            },
            {
              "criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:update_1:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "BA8B4A08-C07D-46C6-BD30-477F54A02C98"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}