CVE-2012-2598
Estado: ModificadaMedia (4.3)—
Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.
CVSS
- Versión: 2.0
- Vector: AV:N/AC:M/Au:N/C:N/I:N/A:P
- Puntuación base: 4.3
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.85%
- Percentil entre todas las CVEs puntuadas: 78
- Fecha de la puntuación: 5/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (1)
CWE
- CWE-119
Referencias
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf
- http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf
- http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf
JSON original (NVD)
Mostrar
{
"id": "CVE-2012-2598",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4.3,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8.6,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "cret@cert.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2012-06-08T18:55:02.317",
"references": [
{
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf",
"tags": [
"Vendor Advisory"
],
"source": "cret@cert.org"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf",
"tags": [
"US Government Resource"
],
"source": "cret@cert.org"
},
{
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-223158.pdf",
"tags": [
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-158-01.pdf",
"tags": [
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input."
},
{
"lang": "es",
"value": "Desbordamiento de búfer en el servidor Web DiagAgent en Siemens WinCC 7.0 SP3 hasta la actualización Update 2 permite a atacantes remotos provocar una denegación de servicio (corte del agente) a través de una entrada manipulada."
}
],
"lastModified": "2026-06-16T23:41:44.717",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "111D0F4D-2B67-46E8-BF8D-5D30EFE561EE"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:update_1:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BA8B4A08-C07D-46C6-BD30-477F54A02C98"
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp3:update_2:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "02711FB5-B13E-4F7F-AD5A-47FEF0A996A1"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cret@cert.org"
}