« Volver al listado

CVE-2012-2515

Estado: ModificadaAlta (9.3)—

Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (7)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-2012-2515",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 9.3,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "authentication": "NONE",
          "integrityImpact": "COMPLETE",
          "accessComplexity": "MEDIUM",
          "availabilityImpact": "COMPLETE",
          "confidentialityImpact": "COMPLETE"
        },
        "acInsufInfo": false,
        "impactScore": 10,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 8.6,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": false,
        "userInteractionRequired": true
      }
    ]
  },
  "affected": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "2012-07-05T03:23:18.480",
  "references": [
    {
      "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html",
      "tags": [
        "Exploit"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://secunia.com/advisories/36905",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://secunia.com/advisories/36914",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.securityfocus.com/bid/36546",
      "tags": [
        "Exploit"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.vupen.com/english/advisories/2009/2793",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://www.vupen.com/english/advisories/2009/2795",
      "source": "ics-cert@hq.dhs.gov"
    },
    {
      "url": "http://retrogod.altervista.org/9sg_emc_keyhelp.html",
      "tags": [
        "Exploit"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://secunia.com/advisories/36905",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://secunia.com/advisories/36914",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/14000/KB14863/en_US/GEIP12-04%20Security%20Advisory%20-%20Proficy%20HTML%20Help.pdf",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/36546",
      "tags": [
        "Exploit"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-131-02.pdf",
      "tags": [
        "US Government Resource"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.vupen.com/english/advisories/2009/2793",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.vupen.com/english/advisories/2009/2795",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple stack-based buffer overflows in the KeyHelp.KeyCtrl.1 ActiveX control in KeyHelp.ocx 1.2.312 in KeyWorks KeyHelp Module (aka the HTML Help component), as used in EMC Documentum ApplicationXtender Desktop 5.4; EMC Captiva Quickscan Pro 4.6 SP1; GE Intelligent Platforms Proficy Historian 3.1, 3.5, 4.0, and 4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX 5.0 and 5.1; GE Intelligent Platforms Proficy Pulse 1.0; GE Intelligent Platforms Proficy Batch Execution 5.6; GE Intelligent Platforms SI7 I/O Driver 7.20 through 7.42; and other products, allow remote attackers to execute arbitrary code via a long string in the second argument to the (1) JumpMappedID or (2) JumpURL method."
    },
    {
      "lang": "es",
      "value": "Múltiples desbordamientos de búfer en el control ActiveX KeyHelp.KeyCtrl.1 en KeyHelp.ocx v1.2.312 en KeyWorks KeyHelp Module (también conocido como el componente HTML Help), tal como se utiliza en EMC Documentum ApplicationXtender Desktop v5.4; EMC Captiva Quickscan Pro v4.6 SP1; GE Intelligent Platforms Proficy Historian v3.1, v3.5, v4.0 y v4.5; GE Intelligent Platforms Proficy HMI/SCADA iFIX v5.0 y v5.1; Proficy Pulse v1,0; Proficy Batch Execution v5,6, SI7 ??E/S Driverv 7.20 hasta 7.42, y otros productos, permite a atacantes remotos ejecutar código de su elección a través de una larga cadena en el segundo argumento del método (1) JumpMappedID o (2) JumpURL."
    }
  ],
  "lastModified": "2026-06-16T23:41:37.450",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:emc:captiva_quickscan_pro:4.6:sp1:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "8B464AC4-7766-47DB-AE36-1E26D244EC67"
            },
            {
              "criteria": "cpe:2.3:a:emc:documentum_applicationxtender_desktop:5.4:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "A361D413-79A2-492B-A675-7A40023BC0D7"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_batch_execution:5.6:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "0D91A768-D643-4601-B11D-2C5FB60B8566"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "612B7F05-3C6D-43CA-8D6C-F0A887789EF5"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:3.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6D29C00B-B754-47C5-BBD0-D63DDD252DA6"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "6BC9F852-EA9A-497D-9ED2-DAF926D0440A"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_historian:4.5:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "2C8C84F4-699E-4D77-AF36-19DF28AE16CC"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "65A4CBC3-3B98-4700-8710-4D4FFCA55315"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\/scada_ifix:5.1:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "5ABA340B-B00B-41EC-8270-68139B63D09A"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_pulse:1.0:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "738ACF30-4F1A-44C6-9A97-46F5566ACC05"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.20:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "641F3A0F-9E07-413D-869C-8E123636DD0A"
            },
            {
              "criteria": "cpe:2.3:a:ge:intelligent_platforms_si7_i\\/o_driver:7.42:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "FA786450-C420-420A-9C5E-49D408B6B3C2"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov"
}