CVE-2012-0222
Estado: ModificadaMedia (5)—
The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet.
CVSS
- Versión: 2.0
- Vector: AV:N/AC:L/Au:N/C:N/I:N/A:P
- Puntuación base: 5
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 3.53%
- Percentil entre todas las CVEs puntuadas: 89
- Fecha de la puntuación: 3/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-119
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2012-0222",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 5,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"authentication": "NONE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "PARTIAL",
"confidentialityImpact": "NONE"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 10,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "cret@cert.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2012-04-02T18:55:01.090",
"references": [
{
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
"source": "cret@cert.org"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
"tags": [
"US Government Resource"
],
"source": "cret@cert.org"
},
{
"url": "http://rockwellautomation.custhelp.com/app/answers/detail/a_id/469937",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-088-01.pdf",
"tags": [
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The FactoryTalk (FT) RNADiagReceiver service in Rockwell Automation Allen-Bradley FactoryTalk CPR9 through SR5 and RSLogix 5000 17 through 20 allows remote attackers to cause a denial of service (out-of-bounds read) via a crafted packet."
},
{
"lang": "es",
"value": "El servicio FactoryTalk (FT) RNADiagReceiver en Rockwell Automation Allen-Bradley FactoryTalk CPR9 hasta SR5 y RSLogix 5000 17 hasta 20 permite a atacantes remotos provocar una denegación de servicio (lectura fuera del límite) a través de un paquete manipulado."
}
],
"lastModified": "2026-06-16T23:36:56.397",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk:cpr9:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A4CDEE93-7510-44B2-9C6F-57D896F2BDCD"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk:cpr9_sr5:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D3288C19-0AA1-45AC-A224-0483587645E0"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:17:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "A3E1F2B5-8BD1-49DF-AEF1-8E4B47C8F5E4"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:18:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "C4165EAF-CA42-4A8D-BE59-275DFB21EA80"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:19:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D1D65EF8-F725-4250-9319-08B6625928ED"
},
{
"criteria": "cpe:2.3:a:rockwellautomation:rslogix_5000:20:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E984E344-7B3A-4A0A-96A9-D2C2E4802ECA"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cret@cert.org"
}