CVE-2010-2772
Estado: ModificadaAlta (7.8)—
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
CVSS
- Versión: 3.1
- Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Puntuación base: 7.8
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 0.55%
- Percentil entre todas las CVEs puntuadas: 44
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-798
Referencias
- http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01
- http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725
- http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr
- http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/
- http://secunia.com/advisories/40682
- http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c
- http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1
- http://www.f-secure.com/weblog/archives/00001987.html
- http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx
- http://www.securityfocus.com/bid/41753
- http://www.vupen.com/english/advisories/2010/1893
- http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22
- http://www.wired.com/threatlevel/2010/07/siemens-scada/
- https://exchange.xforce.ibmcloud.com/vulnerabilities/60587
- http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01
- http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725
- http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr
- http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/
- http://secunia.com/advisories/40682
- http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c
- http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1
- http://www.f-secure.com/weblog/archives/00001987.html
- http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx
- http://www.securityfocus.com/bid/41753
- http://www.vupen.com/english/advisories/2010/1893
- http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22
- http://www.wired.com/threatlevel/2010/07/siemens-scada/
- https://exchange.xforce.ibmcloud.com/vulnerabilities/60587
JSON original (NVD)
Mostrar
{
"id": "CVE-2010-2772",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 6.9,
"accessVector": "LOCAL",
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"authentication": "NONE",
"integrityImpact": "COMPLETE",
"accessComplexity": "MEDIUM",
"availabilityImpact": "COMPLETE",
"confidentialityImpact": "COMPLETE"
},
"acInsufInfo": false,
"impactScore": 10,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": true,
"exploitabilityScore": 3.4,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.8,
"attackVector": "LOCAL",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "LOW",
"confidentialityImpact": "HIGH"
},
"impactScore": 5.9,
"exploitabilityScore": 1.8
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2010-07-22T05:43:58.250",
"references": [
{
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "cve@mitre.org"
},
{
"url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725",
"tags": [
"Press/Media Coverage"
],
"source": "cve@mitre.org"
},
{
"url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr",
"tags": [
"Press/Media Coverage"
],
"source": "cve@mitre.org"
},
{
"url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/",
"tags": [
"Press/Media Coverage"
],
"source": "cve@mitre.org"
},
{
"url": "http://secunia.com/advisories/40682",
"tags": [
"Broken Link"
],
"source": "cve@mitre.org"
},
{
"url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c",
"tags": [
"Not Applicable"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1",
"tags": [
"Broken Link"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.f-secure.com/weblog/archives/00001987.html",
"tags": [
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/bid/41753",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.vupen.com/english/advisories/2010/1893",
"tags": [
"Broken Link"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22",
"tags": [
"Exploit",
"Issue Tracking"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/",
"tags": [
"Press/Media Coverage",
"Third Party Advisory"
],
"source": "cve@mitre.org"
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "cve@mitre.org"
},
{
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725",
"tags": [
"Press/Media Coverage"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr",
"tags": [
"Press/Media Coverage"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/",
"tags": [
"Press/Media Coverage"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://secunia.com/advisories/40682",
"tags": [
"Broken Link"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c",
"tags": [
"Not Applicable"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1",
"tags": [
"Broken Link"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.f-secure.com/weblog/archives/00001987.html",
"tags": [
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/41753",
"tags": [
"Broken Link",
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.vupen.com/english/advisories/2010/1893",
"tags": [
"Broken Link"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22",
"tags": [
"Exploit",
"Issue Tracking"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/",
"tags": [
"Press/Media Coverage",
"Third Party Advisory"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-798"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."
},
{
"lang": "es",
"value": "Siemens Simatic WinCC y sistemas PCS 7 SCADA utiliza una contraseña no modificable en el código, lo cual permite a usuarios locales acceder a una base de datos interna (back-end) y obtener privilegios, como se demuestra en julio de 2010 por el gusano Stuxnet, una vulnerabilidad diferente de CVE-2010-2568."
}
],
"lastModified": "2026-06-16T23:21:29.277",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:6.2:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "9BD0EB37-CFA4-49AE-A952-1A4E2E2EE998"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00"
}
],
"operator": "OR"
}
]
},
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.0:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "963E0E16-2A77-45C8-8708-46B4158C40D0"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "2C026414-5F0C-48E7-A93D-12E2E33AB6CB"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:-:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BD419DE7-CB43-42E7-ACCC-82EA4913E8D2"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "036B082A-1B48-4BA0-A915-4344C70E430D"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D7885AE5-023B-45BC-8E4A-CF796B5757C2"
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25"
}
],
"operator": "OR"
}
]
}
],
"sourceIdentifier": "cve@mitre.org"
}