CVE-2010-0154
Estado: ModificadaMedia (4)—
Directory traversal vulnerability in sla/index.php in the Local Management Interface (LMI) on the IBM Proventia Network Mail Security System (PNMSS) appliance with firmware before 2.5 allows remote authenticated users to read arbitrary files via a .. (dot dot) in the l parameter, related to an "Insecure Direct Object Reference vulnerability."
CVSS
- Versión: 2.0
- Vector: AV:N/AC:L/Au:S/C:P/I:N/A:N
- Puntuación base: 4
Probabilidad de explotación (EPSS)
- Probabilidad de explotación en los próximos 30 días: 1.29%
- Percentil entre todas las CVEs puntuadas: 69
- Fecha de la puntuación: 6/10/2026
EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).
Tecnologías afectadas (2)
CWE
- CWE-22
Referencias
JSON original (NVD)
Mostrar
{
"id": "CVE-2010-0154",
"cveTags": [],
"metrics": {
"cvssMetricV2": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"cvssData": {
"version": "2.0",
"baseScore": 4,
"accessVector": "NETWORK",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"authentication": "SINGLE",
"integrityImpact": "NONE",
"accessComplexity": "LOW",
"availabilityImpact": "NONE",
"confidentialityImpact": "PARTIAL"
},
"acInsufInfo": false,
"impactScore": 2.9,
"baseSeverity": "MEDIUM",
"obtainAllPrivilege": false,
"exploitabilityScore": 8,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"affected": [
{
"source": "cve@mitre.org",
"affectedData": [
{
"vendor": "n/a",
"product": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
]
}
],
"published": "2010-09-14T17:00:01.433",
"references": [
{
"url": "http://www.securityfocus.com/archive/1/513637/100/0/threaded",
"source": "cve@mitre.org"
},
{
"url": "http://www.ventuneac.net/security-advisories/MVSA-10-008",
"tags": [
"Exploit"
],
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/archive/1/513637/100/0/threaded",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.ventuneac.net/security-advisories/MVSA-10-008",
"tags": [
"Exploit"
],
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
],
"vulnStatus": "Modified",
"weaknesses": [
{
"type": "Primary",
"source": "nvd@nist.gov",
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Directory traversal vulnerability in sla/index.php in the Local Management Interface (LMI) on the IBM Proventia Network Mail Security System (PNMSS) appliance with firmware before 2.5 allows remote authenticated users to read arbitrary files via a .. (dot dot) in the l parameter, related to an \"Insecure Direct Object Reference vulnerability.\""
},
{
"lang": "es",
"value": "Vulnerabilidad de salto de directorio en sla/index.php en Local Management Interface (LMI) en el dispositivo IBM Proventia Network Mail Security System (PNMSS), con firmware anterior a la versión 2.5, permite a atacantes remotos autenticados leer ficheros de su elección mediante un .. (punto punto) en el parámetro \"l\", relacionado con una vulnerabilidad \"Insecure Direct Object Reference.\""
}
],
"lastModified": "2026-06-16T23:15:34.850",
"configurations": [
{
"nodes": [
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ibm:proventia_network_mail_security_system_virtual_appliance:*:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "E4AE7B81-387C-446B-B5EF-B897C39D15A1"
}
],
"operator": "OR"
},
{
"negate": false,
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ibm:proventia_network_mail_security_system_virtual_appliance_firmware:1.6:*:*:*:*:*:*:*",
"vulnerable": true,
"matchCriteriaId": "D3A62936-C40C-40DF-8222-ABD6D287CAC5"
}
],
"operator": "OR"
}
],
"operator": "AND"
}
],
"evaluatorImpact": "Per: http://www.ventuneac.net/security-advisories/MVSA-10-008\r\n\r\nAffected Versions\r\n\r\nIBM Proventia Network Mail Security System - virtual appliance (firmware 1.6)",
"sourceIdentifier": "cve@mitre.org"
}