« Volver al listado

CVE-1999-1389

Estado: ModificadaAlta (7.5)—

US Robotics/3Com Total Control Chassis with Frame Relay between 3.6.22 and 3.7.24 does not properly enforce access filters when the "set host prompt" setting is made for a port, which allows attackers to bypass restrictions by providing the hostname twice at the "host: " prompt.

CVSS

Probabilidad de explotación (EPSS)

EPSS (Exploit Prediction Scoring System, de FIRST) estima la probabilidad de que una vulnerabilidad sea explotada en 30 días. Complementa a CVSS (impacto) y a CISA KEV (explotación confirmada).

Tecnologías afectadas (1)

CWE

Referencias

JSON original (NVD)

Mostrar
{
  "id": "CVE-1999-1389",
  "cveTags": [],
  "metrics": {
    "cvssMetricV2": [
      {
        "type": "Primary",
        "source": "nvd@nist.gov",
        "cvssData": {
          "version": "2.0",
          "baseScore": 7.5,
          "accessVector": "NETWORK",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "authentication": "NONE",
          "integrityImpact": "PARTIAL",
          "accessComplexity": "LOW",
          "availabilityImpact": "PARTIAL",
          "confidentialityImpact": "PARTIAL"
        },
        "acInsufInfo": false,
        "impactScore": 6.4,
        "baseSeverity": "HIGH",
        "obtainAllPrivilege": false,
        "exploitabilityScore": 10,
        "obtainUserPrivilege": false,
        "obtainOtherPrivilege": true,
        "userInteractionRequired": false
      }
    ]
  },
  "affected": [
    {
      "source": "cve@mitre.org",
      "affectedData": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ]
    }
  ],
  "published": "1998-05-11T04:00:00.000",
  "references": [
    {
      "url": "http://marc.info/?l=bugtraq&m=90221101925916&w=2",
      "source": "cve@mitre.org"
    },
    {
      "url": "http://www.securityfocus.com/bid/99",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "cve@mitre.org"
    },
    {
      "url": "http://marc.info/?l=bugtraq&m=90221101925916&w=2",
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    },
    {
      "url": "http://www.securityfocus.com/bid/99",
      "tags": [
        "Vendor Advisory"
      ],
      "source": "af854a3a-2127-422b-91ae-364da2661108"
    }
  ],
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "type": "Primary",
      "source": "nvd@nist.gov",
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "US Robotics/3Com Total Control Chassis with Frame Relay between 3.6.22 and 3.7.24 does not properly enforce access filters when the \"set host prompt\" setting is made for a port, which allows attackers to bypass restrictions by providing the hostname twice at the \"host: \" prompt."
    }
  ],
  "lastModified": "2026-06-16T21:50:20.123",
  "configurations": [
    {
      "nodes": [
        {
          "negate": false,
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:3com:total_control_netserver_card:*:*:*:*:*:*:*:*",
              "vulnerable": true,
              "matchCriteriaId": "4E6281AA-520E-4694-94A9-0F40EDB62A98",
              "versionEndIncluding": "3.7.24"
            }
          ],
          "operator": "OR"
        }
      ]
    }
  ],
  "sourceIdentifier": "cve@mitre.org"
}