Schneider-electric
Schneider-electric Modicon M580 Bmeh582040s Firmware: vulnerabilidades y CVE
Schneider-electric Modicon M580 Bmeh582040s Firmware tiene 7 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 4 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE7
Últimos 12 meses0
Críticas4
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2023-6408 | Alta (8.1) | 0.32% | — | 14 feb 2024 | CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when… |
| CVE-2021-22786 | Alta (7.5) | 0.63% | — | 1 feb 2023 | A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products:… |
| CVE-2022-45789 | Crítica (9.8) | 1.5% | — | 31 ene 2023 | A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products:… |
| CVE-2022-45788 | Crítica (9.8) | 1.2% | — | 30 ene 2023 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is… |
| CVE-2022-37301 | Alta (7.5) | 0.75% | — | 22 nov 2022 | A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products:… |
| CVE-2022-37300 | Crítica (9.8) | 0.77% | — | 12 sept 2022 | A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products:… |
| CVE-2021-22779 | Crítica (9.1) | 1.0% | — | 14 jul 2021 | Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process… |
Otros productos de Schneider-electric
Struxureware Data Center Expert · 49Interactive Graphical Scada System · 43Modicon M580 Firmware · 41Modicon M340 Firmware · 39Modicon M340 Bmxp342020 Firmware · 32Modicon M340 Bmxp3420302 Firmware · 28Modicon M340 Bmxp341000 Firmware · 27Ecostruxure Control Expert · 26Modicon M340 Bmxp342000 Firmware · 25Modicon Quantum Firmware · 25Modicon M340 Bmxp3420102 Firmware · 25Easergy T300 Firmware · 24