Schneider-electric
Schneider-electric Modicon M340 Bmxp342030 Firmware: vulnerabilidades y CVE
Schneider-electric Modicon M340 Bmxp342030 Firmware tiene 13 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 4 son críticas y 0 figuran en el catálogo de explotación activa de CISA.
CVE13
Últimos 12 meses0
Críticas4
Explotadas activamente0
Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología
Últimas vulnerabilidades
| CVE | Severidad | EPSS | Explotación activa | Publicada | Descripción |
|---|---|---|---|---|---|
| CVE-2023-6408 | Alta (8.1) | 0.32% | — | 14 feb 2024 | CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when… |
| CVE-2021-22786 | Alta (7.5) | 0.63% | — | 1 feb 2023 | A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products:… |
| CVE-2022-45789 | Crítica (9.8) | 1.5% | — | 31 ene 2023 | A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products:… |
| CVE-2022-45788 | Crítica (9.8) | 1.2% | — | 30 ene 2023 | A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is… |
| CVE-2022-0222 | Alta (7.5) | 0.61% | — | 22 nov 2022 | A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon… |
| CVE-2022-37300 | Crítica (9.8) | 0.77% | — | 12 sept 2022 | A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products:… |
| CVE-2022-22724 | Alta (7.5) | 0.93% | — | 4 feb 2022 | A CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service on ports 80 (HTTP) and 502 (Modbus), when sending a large number of TCP RST or FIN packets to any open TCP port of… |
| CVE-2021-22779 | Crítica (9.1) | 1.0% | — | 14 jul 2021 | Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process… |
| CVE-2015-6462 | Media (5.4) | 0.56% | — | 21 mar 2019 | Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110,… |
| CVE-2015-6461 | Media (5.4) | 0.87% | — | 21 mar 2019 | Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302,… |
| CVE-2017-6017 | Alta (7.5) | 4.8% | — | 30 jun 2017 | A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020,… |
| CVE-2014-0754 | Alta (10) | 9.5% | — | 3 oct 2014 | Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100… |
| CVE-2013-2763 | Media (5) | 2.1% | — | 4 abr 2013 | The Schneider Electric M340 PLC modules allow remote attackers to cause a denial of service (resource consumption) via unspecified vectors. NOTE: the vendor reportedly disputes this issue because it "could not be… |
Otros productos de Schneider-electric
Struxureware Data Center Expert · 49Interactive Graphical Scada System · 43Modicon M580 Firmware · 41Modicon M340 Firmware · 39Modicon M340 Bmxp342020 Firmware · 32Modicon M340 Bmxp3420302 Firmware · 28Modicon M340 Bmxp341000 Firmware · 27Ecostruxure Control Expert · 26Modicon M340 Bmxp342000 Firmware · 25Modicon Quantum Firmware · 25Modicon M340 Bmxp3420102 Firmware · 25Easergy T300 Firmware · 24