« Volver al listado

Moxa

Moxa Oncell G3150-hspa Firmware: vulnerabilidades y CVE

Moxa Oncell G3150-hspa Firmware tiene 9 vulnerabilidades publicadas, 0 de ellas en los últimos 12 meses. 5 son críticas y 0 figuran en el catálogo de explotación activa de CISA.

CVE9
Últimos 12 meses0
Críticas5
Explotadas activamente0

Todas las vulnerabilidades en el catálogo →⭐ Seguir esta tecnología

Últimas vulnerabilidades

CVESeveridadEPSSExplotación activaPublicadaDescripción
CVE-2018-11423Alta (7.5)1.4%—3 jul 2019
There is Memory corruption in the web interface Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior, different vulnerability than CVE-2018-11420.
CVE-2018-11422Crítica (9.8)1.0%—3 jul 2019
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary configuration protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent…
CVE-2018-11421Crítica (9.8)0.91%—3 jul 2019
Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in…
CVE-2018-11420Crítica (9.8)1.5%—3 jul 2019
There is Memory corruption in the web interface of Moxa OnCell G3100-HSPA Series version 1.5 Build 17042015 and prio,r a different vulnerability than CVE-2018-11423.
CVE-2018-11427Alta (8.8)0.58%—3 jul 2019
CSRF tokens are not used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior, which makes it possible to perform CSRF attacks on the device administrator.
CVE-2018-11426Crítica (9.8)1.8%—3 jul 2019
A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web…
CVE-2018-5455Crítica (9.8)1.6%—5 mar 2018
A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only…
CVE-2018-5453Alta (7.5)1.2%—5 mar 2018
An Improper Handling of Length Parameter Inconsistency issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker may be able to edit the element of an HTTP request, causing…
CVE-2018-5449Media (6.5)0.48%—5 mar 2018
A NULL Pointer Dereference issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application does not check for a NULL value, allowing for an attacker to perform a denial of…